  model numbers ac control a24110 a24125 ha48110 ha48125 dc control d24110 d24125 hd48110 hd48125 output specifications 1 operating voltage (47-63 hz) [vrms] 24-280 24-280 48-530 48-530 max. load current 3 [arms] 110 125 110 125 min. load current, [marms] 150 150 150 150 transient overvoltage [vpk] 600 600 1200 1200 max. surge current, (16.6ms) [apk] 1500 1750 1500 1750 max. on-state voltage drop @ rated current [vpk] 1.7 1.7 1.7 1.7 thermal resistance junction to case (r jc ) [c/w] .25 .22 .25 .22 maximum i 2 t for fusing, (8.3 msec.) [a 2 sec] 9,340 12,700 9,340 12,700 max. off-state leakage current @ rated voltage [marms] 10 10 10 10 min. off-state dv/dt @ max. rated voltage [v/sec] 2 500 500 500 500 max. turn-on time 4 1/2 cycle (dc control), 10.0 msec (ac control) max. turn-off time 1/2 cycle (dc control), 40.0 msec (ac control) power factor (min.) with max. load 0.5 0.5 0.5 0.5 input specifications 1 dc control ac control 24v ac/dc control (d prefix) (a prefix) (e suffix) control voltage range 3-32 vdc 90-280 vrms (60hz) 18-36 vrms/vdc max. reverse voltage -32 vdc - - - - - - max. turn-on voltage 3.0 vdc 90 vrms 18 vrms/vdc min. turn-off voltage 1.0 vdc 10 vrms 4.0 vrms/vdc nominal input impedance 1500 ohms (120/240v models) 5 60k ohms 9.0k ohms typical input current 3.4ma @ 5 vdc, 20ma @ 28vdc 5 2ma @ 120 vrms, 4ma @ 240 vrms 3ma @ 24 v general notes 1 all parameters at 25c unless otherwise specified. 2 off-state dv/dt test method per eia/narm standard rs-443, paragraph 13.11.1 3 heat sinking required, for derating curves see page 2. 4 turn-on time for random turn-on versions is 0.02 msec (dc control models). 5 input circuitry for 480v models incorporates active current limiter with 2ma typical input current.. ? zero voltage and random turn-on switching ? panel mount ? internal snubber series 1-110/125. rev. 012908 page 1 of 3 featuring state-of-the-art surface mount technology, these spst-no relays deliver proven reliability in the most demanding applications. output consists of an scr ac switch and is available in zero-cross, random turn-on (phase controllable) and ver- sions with either ac or dc input (coil) control. manufactured in crydom?s iso 9001 certified facility for optimum product performance and reliability. ? 2008 crydom inc., specifications subject to change without notice. ? integrated overvoltage protection by automatic self turn-on (suffix p) series 1-110/125a 120/240, 480 vac - ac output for recommended applications and more information contact: usa: sales support (877) 502-5500 tech support (877) 702-7700 fax (619) 710-8540 crydom inc., 2320 paseo de las americas, ste. 201, san diego, ca 92154 email: sales@crydom.com web site: http://www.crydom.com uk: +44 (0)1202 606030 ? fax +44 (0)1202 606035 crydom ssr ltd., arena business centre, holyrood close, poole, dorset bh17 7fj, email: intsales@crydom.com. germany: +49 (0)180 3000 506
random turn-on (ac & dc control) phase controllable (dc control) example: D24110-10 1.87 (47.5) .78 (19.8) 2.30 (58.4) 1.70 (43.2) .9 (23.0) .45 (11.4) 1.10 (27.9) 8-32 terminal (2 places ) 1.00 (25.4) 6-32 terminal (2 places) 1.80 (45.7) 12 output 3 4 + -- input mounting hole/slot 0.17 (4.3) dia. base plate .125 (3.2) p internal overvoltage protection. relay will self trigger between 450-600 vpk (for 240vac models 125a) & 900-1200vpk (for 480vac models125a) . not suitable for capacitive loads. agencies approval pending. example: d24125p (ac & dc control) example: hd48125p (ac & dc control) 160 80 40 120 0 30 60 120 0 90 20 40 60 80 load current [arms] max ambient temp. [c] power dissipation 100 110 120 base plate temp [c] 125a .5c/w .4c/w 90 1c/w .2c/w 160 80 40 120 0 30 60 120 0 90 20 40 60 80 load current [arms] max ambient temp. [c] power dissipation 100 110 120 base plate temp [c] 110a .5c/w .4c/w 90 1c/w .2c/w current derating curves g input status led. agencies approval pending example: hd48125g note: control voltage range 4.5-32vdc for dc control models. ordering system: combination of the suffixes should be made in the following order: epg-10. example: ha48125epg-10 series 1-110/125 rev. 012908 page 2 of 3 approvals ul e116950 -10 available options e 24v ac/dc input example: a24110e crydom heat sinks offer excellent thermal management and are per fectly matched to the load current ratings of crydom panel mount relays. request crydom?s heat sink specification sheet for all the details. screw torque requirements: 6-32 screws - 10 in./lbs. (1.1 nm), 8-32 and 10-32 screws - 20in./lbs. (2.2 nm) (screws dry without grease.) general specifications dielectric strength 50/60hz input/output/base 4000 vrms insulation resistance (min.) @ 500 vdc 10 9 ohm max. capacitance input/output 8 pf ambient operating temperature range -40 to 80c ambient storage temperature range -40 to 125c mechanical specifications weight: (typical) 3.0 oz. (86.5g) encapsulation: thermally conductive epoxy terminals: screws and saddle clamps furnished, unmounted all dimensions are in inches (millimeters) ? 2008 crydom inc., specifications subject to change without notice. heat tranfer pad (attached) example: d24110h h series 1-110/125a 120/240, 480 vac - ac output for recommended applications and more information contact: usa: sales support (877) 502-5500 tech support (877) 702-7700 fax (619) 710-8540 crydom inc., 2320 paseo de las americas, ste. 201, san diego, ca 92154 email: sales@crydom.com web site: http://www.crydom.com uk: +44 (0)1202 606030 ? fax +44 (0)1202 606035 crydom ssr ltd., arena business centre, holyrood close, poole, dorset bh17 7fj, email: intsales@crydom.com. germany: +49 (0)180 3000 506
hazard of electric shock, explosion, or arc flash. ? disconnect all power before installing or working with this equipment. ? verify all connections and replace all covers before turning on power. failure to follow these instructions will result in death or serious injury. riesgo de descarga electrica o explosion. ? desconectar todos los suministros de energia a este equipo antes de trabajar con este equipo. ? verificar todas las conexiones y colocar todas las tapas antes de energizer el equipo. el incumplimiento de estas instrucciones puede provocar la muerte o lesiones serias. risque de descharge electrique ou explosion ? eteindre toutes les sources d'nergie de cet appareil avant de travailler dessus de cet appareil ? vrifier tous connections, et remettre tous couverts en olace avant de mettre sous de non-suivi de ces instructions provoquera la mort ou des lsions srieuses srieuses. gefahr eines elektrische n schlages oder einer explosion. ? stellen sie jeglichen strom ab, der dieses ger?t versorgt, bevor sie an dem ger?t arbeiten durchfhren ? vor dem drehen auf energie alle anschlsse berprfen und alle abdeckungen ersetzen. unterlassung dieser anweisungen k?nnen zum tode oder zu schweren verletzungen fhren. rischio di scossa elettrica o dell?esplosi one. ? spenga tutta l'alimentazion e che fornisce questa apparecchiatu ra prima del lavorare a questa apparecchiatu ra ? verificare tutti i collegamenti e sostituire tutte le coperture prima della rotazione sull'alimentazi one l'omissione di seguire queste istruz ioni provocher la morte o di lesioni serie risco de descarga elttrica ou explos?o ? desconectar o equipamento de toda energia antes de instalar ou trabalhar com este equipamen to ? verificar todas as conex?es e recolocar todas as tampas antes de religar o equipamento o n?o cumprimento destas instru??es pode levar morte ou les?es srias. risque de dommage materiel et de surchauffe du boitier ? les panneaux latraux du produit peuvent tre chauds. laisser le produit refroidir avant de le toucher. ? respecter les consignes de montage, et notamment les couples de serrage. ? ne pas laisser pntrer de liquide ni de corps trangers l'intrieur du produit. risk of material damage and hot enclosure ? the product's side panels may be hot, allow time for product to cool before touching. ? follow proper mounting instructions including torque values . ? do not allow liquids or foreign objects to enter this product. le non-respect de cette directive peut entra?ner, des lsions corporelles graves ou des dommages matriels. failure to follow this instruction can result in serious injury, or equipment damage. la mancata osservanza di questa precauzione pu causare gravi rischi per l'incolumit personale o danni alle apparecchiature. si no se respetan estas precauciones pueden producirse graves lesiones, da?os materiales. die nichtbeachtung dieser anweisung kann k?rperverletzung oder materialsch?den zur folge haben. a n?o observancia destas precau??es pode provocar a morte, ferimentos graves ou danos materiais. gefahr von materialsch?den und geh?useerhitzung ? die seitenw?nde k?nnen hei? sein. lassen sie das produkt abkhlen, bevor sie es berhren. ? beachten sie die montageanweisungen, ? fhren sie keine flssigkeiten oder fremdk?rper in das produkt ein. rischio di danni materiali e d'involucro caldo ? i pannelli laterali dell'apparecchio possono scottare; lasciar quindi raffreddare il prodotto prima di toccarlo. ? seguire le istruzioni di montaggio corrette. ? non far entrare liquidi o oggetti estranei in questo apparecchio. riesgo de da?os materiales y de sobrecalentamiento de la unidad ? los paneles laterales del producto pueden estar calientes. esperar que el producto se enfre antes de tocarlo. ? respetar las instrucciones de montaje, y en particular los pares de apretado. ? no dejar que penetren lquidos o cuerpos extra?os en el producto. risco de dano material e de aquecimento ? os painis laterais do produto podem estar quentes; d tempo ao produto para arrefecer antes de lhe tocar. ? siga devidamente as instru??es de montagem. ? n?o permita a entrada de lquidos e de objectos estranhos no produto. danger / peligro / danger /gefahr / pericolo / perigo warning / avertissement / warnung /advertencia / avvertenza / aviso series 1-110/125 rev. 012908 page 3 of 3
ann ex ? e nvironm ental i nformati on: the environmental information disclosed in this annex including the eip pollution logo are in compliance with people?s republic of china electronic industry standard sj/t11364 ? 2006, marking for control of pollution caused by electronic information products.  part toxic or hazardous substance and elements name lea d mercury cadmiu m he xav a len t polybrominated polybrominated  (pb) (hg) (cd) chromium (cr (vi)) biphenyls (pbb) diphenyl ethers (pbde) se micondu ct or di e x o o o o o solder x o o o o o  l  - )?   c : !8 l   ? / ,x   + $  c {
? "5  ? ,x )?   c 0  " ? !? e
` ? + $ > ? ? ? sj/t11364 - 2006,  + $  c {
? "5  { 
? a? ?u "    2?   b (= ? y !| y   f? /? j? "2 k a?j ?$?6(8? ?$?`8?gn (pb) (hg) (cd) (cr (vi)) (pbb) (pbde) e'8?( x o o o o o &ty&? x o o o o o    ? 2007 crydom inc., specificat ions subject to change without notice.


▲Up To Search▲   

 
Price & Availability of D24110-10

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X